AC Current Clamp 1000A on Mv & Ma Current Transformers

MV & MA OUTPUT AC CURRENT CLAMP ON CURRENT TRANSFORMER S50 1000AThe round jaw design on the S50 Series AC current clamp on CT along with the high content nickel metal core makes them well suited for power quality applications where high accuracy and low phase shift along with wide frequency are important from 10Hz to 10MHz.

Featured Products

MV & MA OUTPUT AC CURRENT CLAMP ON CURRENT TRANSFORMER S50 1000A


The round jaw design on the S50 Series AC current clamp on CT along with the high content nickel metal core makes them well suited for power quality applications where high accuracy and low phase shift along with wide frequency are important from 10Hz to 10MHz. Measurement range is 1mA to 1200A. The S50 is a general purpose 1200A AC current clamp on CT designed for use with DMMs, power loggers and energy meter calibration instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw. The S50 clamp on CT has an integral 2.5m lead terminated. The rounded jaw design on this current clamp makes it well-suited for power applications where high accuracy 0.1% and low phase shift and wide frequency response are important. 
 

APPLICATIONS

  • Power quality analyzer(PQA)
  • power and harmonic meters
  • Phase angle meter
  • Energy meter calibrator
  • Measuring around cable bundles
  • Power load monitoring
  • Data logging/recording
  • Waveform analysis(oscilloscopes meter)
 

FEATURES

  • Measurement range of 1mA to 1200A AC
  • Improved ergonomic design & easy operation
  • High content permalloy core
  • Frequency 10Hz-10MHz Bandwidth
  • Holding wire diameter: φ52mm
  • Conforms to EN 61010, 600V CAT III
  • Low phase shift for power measurement
  • Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters
  • UL, CE mark
 

PARAMETERS

Electrical parameters
Ratio1000: 1 , 2000:1, 1000:5 (customized)
Accuracy class0.1%, 0.2%, 0.5%
Primary current0 - 500A AC and 0-1000A AC
Signal output1mV/A, 1mA/A
Secondary voltage0 - 0.5V AC and  0 - 1V AC;
Secondary current0-1A or 0-5A AC
Max. Cont. Input current1200A
Load capacity≤4Ω
Over voltage categoryCAT III 600V
Frequency range10Hz-10MHz
Dielectric strength3KV 50Hz/60Hz  at 1minute
Temperature range-40°C to +55°C
Output2.5 meter cable with D01 or BNC connector
Max. voltage not insulated conductors600 V
StandardEN 61010-1, EN 61010-2-032, IEC60044-1
Installationclamp type
Output modelead output(2.5m)
Accuracy (1000A Range) 
0-10A≤0.5%
10-100≤0.2%
10-1200A≤0.1%
Phase Shift(1000A Range)
0-10A≤0.5°
10-100≤0.2°
100-1200A≤0.1°
Mechanical parameters
Dimensions (L x W x H) (mm)105 x 218 x 30
Weight (g)650
Holding wire diameter (mm)φ52
Max. jaw opening (mm)52
Jaw colorRed & Grey
MaterialPC+ABS, UL94 V0

photo

Mv & Ma AC Current Clamp on Current Transformer 1000A
 

Contact us