RS485 Smart Sensor with Open Split Core Current Transformer

Specification DataMeasuring Voltage Range0~450VMeasuring Current Range100A/200A/400A/500A OptionalFrequency50-60HzAccuracy Class1Reference StandardIEC62052-11,IEC62053-21Starting Current 0.004IbPower Consumption<=30mA(5~18v)Constant1000imp/kWhInstallationDin Rail TypeDimension14.2*15.5*21mmOperation Temperature-40~80ºCRe

Featured Products

RS485 Smart Sensor with Open Split Core Current TransformerRS485 Smart Sensor with Open Split Core Current TransformerRS485 Smart Sensor with Open Split Core Current Transformer
Specification DataMeasuring Voltage Range0~450V
Measuring Current Range100A/200A/400A/500A Optional
Frequency50-60Hz
Accuracy Class1
Reference StandardIEC62052-11,IEC62053-21
Starting Current 0.004Ib
Power Consumption<=30mA(5~18v)
Constant1000imp/kWh
InstallationDin Rail Type
Dimension14.2*15.5*21mm
Operation Temperature-40~80ºC
Related Humidity<=75%
CommunicationRS485

RS485 Smart Sensor with Open Split Core Current TransformerRS485 Smart Sensor with Open Split Core Current TransformerRS485 Smart Sensor with Open Split Core Current TransformerRS485 Smart Sensor with Open Split Core Current TransformerRS485 Smart Sensor with Open Split Core Current Transformer          Cautions of Smart Sensor:
            1.Current value- Please specify your measurement range as per your application, for example if you are going to
            use it for detecting and sensing mA level or high  current range such as 500A/600A shall be first factor.
            2.AC,DC,or both AC&DC shall be the second factor. Now current sensor on the market usually are AC or DC type.
            But if you need both AC& DC you may need to use IVY brand- AC DC leakage sensor.
            3.Parameters-Please confirm what kind of parameters shall be measured or detected. For example our smart sensor
            with shunt can readout current, voltage,kWh, kVar, Cos
φ, Hz, THF, current cycle, starting waveform.
            4.Communication-RS485,M-bus, UART serial port are optional, if you have more requirements we can also develop for you.
            5.Installation Method, after making above decision you may also need to confirm the output terminal type, for example we have
            shunt / terminal / pillar / pins/ cable etc.
            6.
As there are many models of smart electrical sensor, plz refer to the detailed specification and use it as per the instruction.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours