60A single-phase ring CT current transformer

CurrentCoil TurnsBurdenDielectric StrengthAccuracyRated Frequency5(60)A2000/250010ΩMore than 4000VAC0.1 Class50~60HzCurrent Ratio ±%Phase Error ±(\')5%Ib20%Ib100%Ib800%IMax5%Ib20%Ib100%Ib800%IMax0.100.100.100.100.10108555            Cautions of Current Transformer:    &

Featured Products


60A Single Phase Toroidal CT Current Transformer60A Single Phase Toroidal CT Current Transformer60A Single Phase Toroidal CT Current Transformer
CurrentCoil TurnsBurdenDielectric StrengthAccuracyRated Frequency
5(60)A2000/250010ΩMore than 4000VAC0.1 Class50~60Hz
Current Ratio ±%Phase Error ±(')
5%Ib20%Ib100%Ib800%IMax5%Ib20%Ib100%Ib800%IMax
0.100.100.100.100.10108555

60A Single Phase Toroidal CT Current Transformer60A Single Phase Toroidal CT Current Transformer
60A Single Phase Toroidal CT Current Transformer60A Single Phase Toroidal CT Current Transformer60A Single Phase Toroidal CT Current Transformer60A Single Phase Toroidal CT Current Transformer            Cautions of Current Transformer:

             1.Suggestions of choosing (Take ct for energy meter as example)
            (1)
Please offer the primary current and secondary current or primary current and ratio as per your requirements.
            For example if the energy meter is 5(80)A, you may need a current transformer with current to 80A or 100A.
            (2)Please specify the accuracy as per secondary circuit or accuracy requirements of energy meter.
            For example If it's industrial degree meter then you may need high accuracy current transformer such Class 0.5S, Class 0.01/0.02.

            (3)Customized terminal design for your primary circuit - if it's not good for fixing or you need to integrated with
            relay/shunt/terminal block etc then you may need to offer your drawing for design and adapt to the application.

            (4)Plz choose the suitable secondary output terminal, if you need to solder and fix it on PCB then you may need to
            choose PCB/pin type, for other situation you can use lead wires directly.
 
            2.Standard of good current transformer
            (1)Plastic casing instead of traditional tape which is anti-dust,ant-shock,anti-flaming for security.
            (2)Central rubber hole is more flexible for installation.
            (3)Moreover current transformer become advanced and smart, hence 500mT permanent magnetic immunity,
            high accuracy when cosφ=0.5, smart CT with M-bus or RS485 communication are welcomed as well.