Name: 0.333V output 1A 5A window type Current Transformer CT core for power transformer IEC, ETL
Output secondary 5A split core current transformer :
Model 1:
GWSCCTSB0203
Turn ratio: 100:5A 150:5A 200:5A 250:5A 300:5A 400:5A current transformer China
Model 2:
GWSCCTSB0508
Turn ratio:250:5A 300:5A 400:5A 500:5A 600:5A 750:5A 1000:5A split core transformer
Model 3:
GWSCCTSB0512
Turn Ratio:600:5A 750:5A 1000:5A 1250:5A 1500:5A 2000:5A 3000:5A current CT
Model 4:
GWSCCTSB0812
Turn ratio: 500:5A600:5A 750:5A 1000:5A 1250:5A 1500:5A split core China
Model 5:
GWSCCTSB0816
Turn Ratio:500:5A 600:5A 750:5A 1000:5A 1250:5A 1500:5A high quality split core current transformer with ROHS ,ETL approval.
Output secondary rated 1A split transformer :
Model 1: GWSCCTSB0203
Turn ratio :100:1A 150:1A 200:1A 250:1A 300:1A 400:1A split core CT
Model 2: GWSCCTSB0508
Turn ratio: 200:1A 300:1A 400:1A 500:1A 600:1A 750:1A 1000:1A
Model 3: GWSCCTSB0512
Turn Ratio:500:1A 600:1A 750:1A 1000:1A 1250:1A 1500:1A 2000:1A 3000:1A
Model No.: GWSCCTSB0812
Model No.GWSCCTSB0816
Turn ratio: 600:1A 750:1A 1000:1A 1250:1A 1500:1A 2000:1A 2500:1A 3000:1A 4000:1A split transformer ETL made in China
MA or 0.333-3.53V RATED SECONDART OUTPUT :
1 va 2 va 5v 10 15 30VA 0.333-3.53V Output
split core ct/split current transformer for power factor correction;
0.333-3.53v Output split core current transformer
split current sensor for correction;
0.333-3.53v current transducer/split current sensor for correction
0.333-3.53V rated secondary output split core current transformer :
Model No 1 :GWSCCTSA010
Ratio : 3000:1
Rated input: 5A 10A 20A 50A 75A
Accuracy class: 1.0s 3.0s
Rated primary current :120A
Protection: 5 times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A
Model No.2 :GWSCCTSA016
Ratio :3000:1
Rated input: 75A 100A 150A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 300A
Protection : 5 times Protection, 10 times protection
Model No. 3:GWSCCTSA024
Ratio : 3000:1
Rated input: 100A 150A 200A 250A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 540A
Protection : 5 times Protection, 10 times protection
Model No.4:GWSCCTSA035
Rated input: 200A 300A 400A 600A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 600A
Protection : 5 times Protection, 10 times protection
Frequency: 50--400Hz
A2. Split Core Current Transformers \mA or 0.333-3.53V Rated Secondary Output
1.Applications:
Current, power, energy, monitoring devices;Relay protection devices;Power Factor Correction devices.
2. Specifications:Rated Primary current: 100-5000Aac;Rated Secondary current:5 or 1Aac;Rated load: 1, 2.5, 5.0, 10, 30VA;Accuracy: 0.5, 1.0, 3.0 Class;
3.Rated Short-time thermal current (Ith):20In
Rated Dynamic current (Idyn):2.5Ith;
Case Material: UL flame retardant rating 94-V0;
Highest Voltage for Equipment Um (rms):720 Vac;
Rated Power-Frequency Withstand Voltage;(rms):3,000 Vac
Frequency Range:50/60Hz;Operating Temperature: -15 to degree;
Standard:IEC 60044-1 .
Other current transformer :
The following pictures show you about all finished current transformers in the warehouse which are waiting for packing into boxes. And then they will be packed into export standard cartons with strong pallets so that can make sure the goods safe arrival at your destination place.
About us:
Tianjin Grewin Technology Co.,ltd. has always laying great emphasis on our core
business philosophy "Quality and Honesty First ".
Our strongly advantages as below:
1. Our transformer quality lifetime: 10 Years.
2. Specialty Sales service: 5 -10 Years
3. Proficient experience workers on average:Around 5 Years.
4. Equipments:Advanced winding machines imported from Italy.
5. Test: 100% test before the shipment
As a professional leading and a main exporter of a wide variety of electronic components in China for many years, we adhere to new products, quality to meet the needs of you and welcome all of you to negotiate!
We have abtained SGS Audit Supplier in China and VDE,ETL,CE,ROHS,ISO9000 Approal. Guarantee quality is the first:
Parameters :
1.Models No.
2.Or accuracy ,rated output voltage andcurrent;
3.frequency and dimension.
4.Order qty/batch
5.Samples qty
Thank you for your understand and support
Contact Information:
TIANJIN GREWIN TECHNOLOGY CO.,LTD
Add:Meinian Plaza.No.16 Dongting Road,Hexi Distr,Tianjin,China .
Tel: +86-22-84943756
Web: transformer.en.made-in-china.com
GWSCCTSB Series Split Core Current Transformer (Features) |
Low cost |
5 standard sizes |
Split core design, safer, easier installation, and portable |
GWSCCTSB Series Split Core Current Transformer (Applications) |
Current, power, energy, monitoring devices |
Relay protection devices |
Power Factor Correction devices |
Output secondary 5A split core current transformer :
Model 1:
GWSCCTSB0203
Turn ratio: 100:5A 150:5A 200:5A 250:5A 300:5A 400:5A current transformer China
Model 2:
GWSCCTSB0508
Turn ratio:250:5A 300:5A 400:5A 500:5A 600:5A 750:5A 1000:5A split core transformer
Model 3:
GWSCCTSB0512
Turn Ratio:600:5A 750:5A 1000:5A 1250:5A 1500:5A 2000:5A 3000:5A current CT
Model 4:
GWSCCTSB0812
Turn ratio: 500:5A600:5A 750:5A 1000:5A 1250:5A 1500:5A split core China
Model 5:
GWSCCTSB0816
Turn Ratio:500:5A 600:5A 750:5A 1000:5A 1250:5A 1500:5A high quality split core current transformer with ROHS ,ETL approval.
Output secondary rated 1A split transformer :
Model 1: GWSCCTSB0203
Turn ratio :100:1A 150:1A 200:1A 250:1A 300:1A 400:1A split core CT
Model 2: GWSCCTSB0508
Turn ratio: 200:1A 300:1A 400:1A 500:1A 600:1A 750:1A 1000:1A
Model 3: GWSCCTSB0512
Turn Ratio:500:1A 600:1A 750:1A 1000:1A 1250:1A 1500:1A 2000:1A 3000:1A
Model No.: GWSCCTSB0812
Model No.GWSCCTSB0816
Turn ratio: 600:1A 750:1A 1000:1A 1250:1A 1500:1A 2000:1A 2500:1A 3000:1A 4000:1A split transformer ETL made in China
MA or 0.333-3.53V RATED SECONDART OUTPUT :
1 va 2 va 5v 10 15 30VA 0.333-3.53V Output
split core ct/split current transformer for power factor correction;
0.333-3.53v Output split core current transformer
split current sensor for correction;
0.333-3.53v current transducer/split current sensor for correction
Part Number | Ratio | Measuring | Protection | Frequency (Hz) | Outline Dimensions ID-L-W-H (mm) | ||
Rated Input | Accuracy Class | Rated Accuracy Limit Primary Current (A) | Accuracy Class | ||||
GWSCCTSA010 | 3000:1 | 5,10,20,50,75 | 1.0,3.0 | 120 | 5P,10P | 50~400 | 10 -29.4-26.4-41.7 |
GWSCCTSA016 | 75,100,150 | 0.5,1.0 | 300 | 5P,10P | 50~400 | 16 -36.9-39.2-52.9 | |
GWSCCTSA024 | 100,150,200,250 | 0.5,1.0 | 540 | 5P,10P | 50~400 | 24 -51.2-47-70.2 | |
GWSCCTSA035 | 200,300,400,600 | 0.5,1.0 | 600 | 5P,10P | 50~400 | 35 -65.8-51.2-83.5 |
0.333-3.53V rated secondary output split core current transformer :
Model No 1 :GWSCCTSA010
Ratio : 3000:1
Rated input: 5A 10A 20A 50A 75A
Accuracy class: 1.0s 3.0s
Rated primary current :120A
Protection: 5 times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A
Model No.2 :GWSCCTSA016
Ratio :3000:1
Rated input: 75A 100A 150A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 300A
Protection : 5 times Protection, 10 times protection
Model No. 3:GWSCCTSA024
Ratio : 3000:1
Rated input: 100A 150A 200A 250A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 540A
Protection : 5 times Protection, 10 times protection
Model No.4:GWSCCTSA035
Rated input: 200A 300A 400A 600A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 600A
Protection : 5 times Protection, 10 times protection
Frequency: 50--400Hz
A2. Split Core Current Transformers \mA or 0.333-3.53V Rated Secondary Output
1.Applications:
Current, power, energy, monitoring devices;Relay protection devices;Power Factor Correction devices.
2. Specifications:Rated Primary current: 100-5000Aac;Rated Secondary current:5 or 1Aac;Rated load: 1, 2.5, 5.0, 10, 30VA;Accuracy: 0.5, 1.0, 3.0 Class;
3.Rated Short-time thermal current (Ith):20In
Rated Dynamic current (Idyn):2.5Ith;
Case Material: UL flame retardant rating 94-V0;
Highest Voltage for Equipment Um (rms):720 Vac;
Rated Power-Frequency Withstand Voltage;(rms):3,000 Vac
Frequency Range:50/60Hz;Operating Temperature: -15 to degree;
Standard:IEC 60044-1 .
Other current transformer :
The following pictures show you about all finished current transformers in the warehouse which are waiting for packing into boxes. And then they will be packed into export standard cartons with strong pallets so that can make sure the goods safe arrival at your destination place.
About us:
Tianjin Grewin Technology Co.,ltd. has always laying great emphasis on our core
business philosophy "Quality and Honesty First ".
Our strongly advantages as below:
1. Our transformer quality lifetime: 10 Years.
2. Specialty Sales service: 5 -10 Years
3. Proficient experience workers on average:Around 5 Years.
4. Equipments:Advanced winding machines imported from Italy.
5. Test: 100% test before the shipment
As a professional leading and a main exporter of a wide variety of electronic components in China for many years, we adhere to new products, quality to meet the needs of you and welcome all of you to negotiate!
We have abtained SGS Audit Supplier in China and VDE,ETL,CE,ROHS,ISO9000 Approal. Guarantee quality is the first:
Parameters :
1.Models No.
2.Or accuracy ,rated output voltage andcurrent;
3.frequency and dimension.
4.Order qty/batch
5.Samples qty
Thank you for your understand and support
Contact Information:
TIANJIN GREWIN TECHNOLOGY CO.,LTD
Add:Meinian Plaza.No.16 Dongting Road,Hexi Distr,Tianjin,China .
Tel: +86-22-84943756